Determination of hydrogen using the heat extraction method is a special requirement for the characterization of steel, steel alloys, copper and other metals. ELTRA’s H-500 is designed for the rapid and accurate determination of hydrogen in these materials.
The H-500 analyzer uses the heat extraction technique and is equipped with a resistance furnace with quartz tube. The temperature can be set up to 1000 °C in steps of 1 °C. The usual working range of the H-500 is about 900° to 1000° C.
ELTRA’s H-500 can be customized to the requirements of the user. The analyzer carries up to two different sensitivities of the detectors to allow highest precision for a variety of applications.
alloys, copper, steel
Measured elements | hydrogen |
Samples | metals, steel |
Furnace alignment | horizontal / tilting function |
Sample carrier | - |
Field of application | engineering / electronics, glass / ceramics, steel / metallurgy |
Furnace | resistance furnace with quartz tube, adjustable up to 1000 °C (operating temperature 900 - 1000 °C) |
Detection method | thermal conductivity |
Maximum sample size | ø 13 x 60 mm |
Typical analysis time | 3 - 15 min |
Chemicals required | Schuetze reagents, magnesium perchlorate, sodium hydroxide |
Gas required | nitrogen 99.995 % pure (2 - 4 bar / 30 - 60 psi) |
Power requirements | 230 V, 50/60 Hz, 2 A, max. 450 W |
Dimensions (W x H x D) | 75 x 52 x 60 cm |
Weight | ~ 40 kg |
Required equipment | PC, monitor, balance (resolution 0.0001g) |
Optional accessories | voltage stabilizer 5 KVA |
Operating the H-500 is simple and safe. After weighing the sample on the interfaced electronic, the weight is transferred to the connected PC. It is also possible to enter the weight manually via the H-500 software.
The sample is placed into the cold zone of the horizontally positioned furnace.After starting the analysis, the furnace is rotated upwards for the sample to fall into the hot zone. By adding nitrogen as carrier gas hydrogen diffuses out and is carried into a sensitive thermal conductivity cell.
The typical analysis time is about 3 to 15 minutes. Detector signals and instrument parameters are displayed during analysis. Evaluation of the signals and display of the results are done automatically; the data can be transferred to a laboratory information management system (LIMS). The H-500 requires minimum maintenance. The particle filters and chemicals which need to be maintained are easily accessible.
Content may be subject to modifications or corrections